Sensors and Materials
Contents

  MYU
Sensors and Materials
1-23-3-303 Sendagi, Bunkyo-ku, Tokyo 113-0022, Japan
Tel: 81-3-3821-2930
Fax: 81-3-3827-8547
 




Sensors and Materials  ISSN 0914-4935

Vol. 28 No. 12
Special Issue on International Conference on BioSensors, BioElectronics, BioMedical Devices, BioMEMS/NEMS and Applications 2015 (Bio4Apps 2015)

Guest Editor: Hirofumi Nogami (Kyushu University, Japan)

Preface

  • We designed and synthesized a polyethylene film that immobilizes antibodies via desthiobiotin– avidin interaction by grafting poly(acrylic acid) (PAAc) and biotin to its surface. The desthi... Read More

  • In this work, we assessed the ability of a fiber-optic biochemical gas sensor (bio-sniffer) to directly and nondestructively measure gaseous formaldehyde (FA) released from food. In the biosniffe... Read More

  • We have developed a solid-type pH sensor for dairy wagyu-rumen measurements. The pH sensor is composed of a sensing electrode of indium tin oxide (ITO) film and a metal–oxide– semicon... Read More

  • The brain–machine interface (BMI) or direct neural interface (DNI) has been intensively investigated for patients with physical function disorders. These interfaces are direct communication... Read More

  • An optical biosniffer for dimethyl sulfide (DMS; seaweed-odor substance) was constructed by immobilizing flavin-containing monooxygenase type 3 (FMO3) onto the tip of a fiber optic oxygen sensor ... Read More

  • High-performance electrodes intended for retinal prosthesis were fabricated and evaluated. Iridium oxide (IrOx) was introduced as a high-performance material. A three-dimensional (3D) structure w... Read More

  • Fluorescence imaging is a powerful tool for studying the functions of nitric oxide (NO). To improve this method of studying the mechanisms of NO related with behaviors in freely moving animals, w... Read More

  • We have studied the construction of an electrochemical immunochromatography platform as one of the point-of-care testing devices from both experimental and theoretical aspects. In the electrochem... Read More

  • We developed a microoptical displacement sensor on which a thermal sensor was integrated. The sensor was 3 × 3 mm2 in size and 0.7 mm thick including the optical power source and thermal se... Read More


S&M1287

Research Paper of Special Issue

S&M1287
Capture and Release of Target Cells Using a Surface That Immobilizes an Antibody via Desthiobiotin–Avidin Interaction
Tsuyoshi Kimura, Naoko Nakamura, Nao Sasaki, Yoshihide Hashimoto, Shimon Sakaguchi, Shunsaku Kimura, and Akio Kishida
pp. 1255-1263
http://dx.doi.org/10.18494/SAM.2016.1287
Published on December 14, 2016
PDF (open access)

S&M1288

Research Paper of Special Issue

S&M1288
Direct Measurement of Gaseous Formaldehyde from Food with a Fiber-Optic Biochemical Gas Sensor (Bio-sniffer)
Koji Toma, Kumiko Miyajima, Shin-ichi Sawada, Takahiro Arakawa, Hiroyuki Kudo, Kazunari Akiyoshi, and Kohji Mitsubayashi
pp. 1265-1272
http://dx.doi.org/10.18494/SAM.2016.1288
Published on December 14, 2016
PDF (open access)

S&M1289

Research Paper of Special Issue

S&M1289
Developing a Solid-State pH Sensor for Wagyu-Rumen Monitoring
Lan Zhang, Jian Lu, Hirofumi Nogami, Hironao Okada, and Toshihiro Itoh
pp. 1273-1281
http://dx.doi.org/10.18494/SAM.2016.1289
Published on December 14, 2016
PDF (open access)

S&M1290

Research Paper of Special Issue

S&M1290
Feasibility Study of High-Performance Implantable Stimulation Electrode with Nanocomposite Gel Coating as a Brain–Machine Interface Device
Hiroyuki Tashiro, Yasuo Terasawa, Kazutoshi Haraguchi, Koji Osawa, Toshihiko Noda, Takashi Tokuda, and Jun Ohta
pp. 1283-1293
http://dx.doi.org/10.18494/SAM.2016.1290
Published on December 14, 2016
PDF (open access)

S&M1291

Research Paper of Special Issue

S&M1291
Fiber Optic Biosniffer (Biochemical Gas Sensor) for Gaseous Dimethyl Sulfide
Hirokazu Saito, Yuki Hashimoto, Takeshi Minamide, Takuo Kon, Koji Toma, Takahiro Arakawa, and Kohji Mitsubayashi
pp. 1295-1301
http://dx.doi.org/10.18494/SAM.2016.1291
Published on December 14, 2016
PDF (open access)

S&M1292

Research Paper of Special Issue

S&M1292
Performance Improvement of a Micro-stimulus Electrode for Retinal Prosthesis by Introducing a High-Performance Material and a Three-Dimensional Structure
Takumi Fujisawa, Toshihiko Noda, Megumi Hayashi, Ryo Kobe, Hiroyuki Tashiro, Hiroaki Takehara, Kiyotaka Sasagawa, Takashi Tokuda, Chung-Yu Wu, and Jun Ohta
pp. 1303-1315
http://dx.doi.org/10.18494/SAM.2016.1292
Published on December 14, 2016
PDF (open access)

S&M1293

Research Paper of Special Issue

S&M1293
Miniature Imaging Device with a Portable Processing System for Fluorescence Detection of Nitric Oxide in Living
Anek Wuthayavanich, Makito Haruta, Hiroaki Takehara, Toshihiko Noda, Kiyotaka Sasagawa, Takashi Tokuda, and Jun Ohta
pp. 1317-1327
http://dx.doi.org/10.18494/SAM.2016.1293
Published on December 14, 2016
PDF (open access)

S&M1294

Research Paper of Special Issue

S&M1294
Effects of Electrode Placement and Measurement Time on Electrochemical Signal of Redox Species Flowing through Porous Material
Wataru Iwasaki, Ramachandra Rao Sathuluri, Ryoji Kurita, Osamu Niwa, and Masaya Miyazaki
pp. 1329-1335
http://dx.doi.org/10.18494/SAM.2016.1294
Published on December 14, 2016
PDF (open access)

S&M1295

Research Paper of Special Issue

S&M1295
Temperature Compensation for a Microoptical Displacement Sensor Using an Integrated Thermal Sensor
Toshihiro Takeshita, Yuma Hayashida, Hideyuki Ando, Hirofumi Nogami, and Renshi Sawada
pp. 1337-1347
http://dx.doi.org/10.18494/SAM.2016.1295
Published on December 14, 2016
PDF (open access)
Vol. 28 No. 12

Copyright(C) MYU K.K. All Rights Reserved.